Control philosophy for a Feldspar plant should start from the two things an operator must never do: run the chamber empty and overfill the screen. Everything else can be automated around those limits.
Control and automation
A practical scope is interlocked start-up and shutdown, a belt scale on the primary feed, level indication in the surge bin, and trips on bearing temperature and belt misalignment. That covers most of the risk for a modest cost.
Full SCADA with trend historians is worth it where the plant runs unattended or where the owner operates several sites. On a single-shift plant, the same money is better spent on a proper control room and a maintenance store.
What we need from the owner
Feed sample and analysis, target output and specification, site location and power available, and the commercial model for the product. With those we issue a mass balance, an equipment list, a power demand and a budget range before any drawing is committed.
Where this fits
Route: Mineral processing. Feed: Feldspar from a pegmatite body, bulk density 2.60 t/m³, work index 11–13 kWh/t. Product: ceramic grade powder.
Related: solutions index · process routes · request a proposal.